fbpx

Mobile trailer type diesel generator set

Table of Contents
    Add a header to begin generating the table of contents

    1. Why choose mobile diesel generator set?

    At present, in addition to the traditional European and North American markets, the demand for mobile type diesel genset is increasing in emerging markets such as the Middle East, Africa, Southeast Asia, Oceania, and South America. In particular, the demand in the Middle East and Africa region mainly comes from infrastructure construction, oil exploration industry and the power supply gap caused by imperfect power facilities. This region has huge economic potential.

    The mobile  genset is innovative in design, high mobility, low center of gravity, safe braking, well-manufactured and modern appearance. It adopts leaf spring suspension structure, high strength and good rigidity. The mobile trailer type generator set is easy to move, flexible to operate, and has good sealing and safety. And equipped with hand brake, air brake, rear tail lights and other systems, in line with road driving requirements. Widely used in construction sites, highway, railway construction and temporary locations where electricity is used.

    The mobile genset can be divided into hand-push vehicle-mounted generator sets, two-wheel vehicle-mounted generator sets, four-wheel vehicle-mounted generator sets, automobile power stations, trailer power stations, mobile low-noise power stations, mobile container power stations, power engineering vehicles, etc.

    2. Features of common mobile generator set

    2.1. Leaf spring suspension structure, equipped with mechanical parking brake (hand brake) and air brake connected to the tractor.

    2.2. The generator set trailer adopts a height-adjustable bolt-type tractor, which is suitable for tractors of various heights, with large turning angle and high mobility.

    2.3. There are mechanical support devices at the four corners of the frame, operation and maintenance platforms on three sides of the trailer, and pedals at the tail.

    3. Features of low noise mobile generator set

    3.1. Significant low noise performance, the generator noise limit is 75dB(A) (1m away from the unit).

    3.2. The overall design of the unit is compact in structure, small in size, novel in appearance.

    3.3. Multi-layer shielding impedance mismatched sound insulation cover.

    3.4. High-efficiency noise reduction multi-channel intake and exhaust, intake and exhaust channels to ensure sufficient power performance.

    3.5. Large impedance composite muffler.

    3.6. Large-capacity base fuel tank.

    3.7. The special quick-opening cover plate is convenient for maintenance.

    4. Featured configuration

    4.1. Traction: It adopts movable hook, 180° turntable, flexible steering and convenient operation.

    4.2. Braking: At the same time, it has reliable air brake connector and manual brake system to ensure the safety in driving.

    4.3. Support: In order to ensure the stability of the mobile trailer generator during operation, it is equipped with 4R mechanical or hydraulic support device.

    4.4. Doors and windows: There are ventilation windows in the front, two-sided doors in the rear, and doors on both sides for operators to enter and exit.

    4.5. Generator canopy size: The canopy size is customized according to the size of the specification, and the operator can walk around, which is convenient for operation and maintenance.

    4.6. Appearance: The paint is made of high molecular polyurethane paint, the color can be customized, and the exhaust pipe adopts upper exhaust or lower exhaust according to customer requirements. The warning signs on the generator canopy can also be customized.

    4.7. Fire fighting: The vehicle can be equipped with fire extinguishers or advanced automatic fire extinguishing system.

    5. Precautions

    A “NO OPERATION” or similar warning sign should be hung on the start switch or operating lever before maintaining or repairing the generator set. Do not allow unauthorized persons to approach the engine while maintenance or repairs are being performed on the generator set. And press the emergency stop button on the generator set control panel, the generator output switch should be in the OFF position. According to working conditions, the operator should wear a safety helmet when entering the generator set installation site, and wear protective eyewear and other protective equipment when necessary. Wear ear protection when running the engine in an enclosed place to prevent hearing damage. Do not wear oversized protective clothing and jewelry on the work site, which may hang on the joystick or other parts of the engine. Make sure all guards or covers are securely in place on the engine. Do not put maintenance solutions in glass containers as glass containers are fragile.

    6. The maintenance of starting batteries

    When one of the following situations occurs, the charging time is allowed to be extended appropriately:

    6.1. The batteries storage time is more than 3 months, and the charging time can be 8 hours.

    6.2. The ambient temperature is continuously above 30°C (86°F) or the relative humidity is continuously higher than 80%, and the charging time is 8 hours.

    6.3. If the batteries are stored for more than 1 year, the charging time can be 12 hours.

    6.4. When charging is about to end, check whether the electrolyte level is sufficient. If necessary, add a standard electrolyte with the correct specific gravity (1:1.28).

    6.5. In addition, in order to prevent the pollution in the battery cell from being discharged in time due to long-term closure, and to prevent water droplets from condensing on the inner top wall of the cell, care should be taken to open the special vent hole to facilitate proper air circulation.

    7. The economic advantage of mobile generator set

    At present, the problem of global power shortage is becoming more and more serious, and people’s requirements for environmental protection are also getting higher and higher. As a backup power source for the power supply network, mobile diesel generator sets have been widely used. The mobile trailer type generator set can be placed indoors or directly outdoors. The canopies of mobile trailer generators are silent designed. While several generators are placed in the machine room, the electric staff can also work inside and some other electrical equipments can also be placed inside. So it will save space for customers. The canopies of mobile trailer generators are also weatherproof designed, can be placed outdoors, which saves customers a lot of money to build a machine room.

    Share This Article
    BY MG POWER
    cummins series genset
    Cummins series
    perkins series genset
    Perkins series
    mtu series genset
    MTU series
    doosan series genset
    Doosan series
    yuchai series genset
    Yuchai series
    滚动至顶部